dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Accumulator HVAC|Description and Operation|Page 4029 > < Wheel Fastener|Front|Page 4024
Page 1
background image

Accumulator HVAC: Description and Operation

Accumulator - Typical

An accumulator is used on 2.0L LHD models. The accumulator is mounted in the engine compartment between the evaporator outlet and the compressor
suction port. An integral mounting bracket is used to secure the accumulator to the right side rail with a bolt. A threaded fitting on the top of the
accumulator canister provides the port through which the A/C low pressure switch monitors the refrigerant system pressures.

The accumulator cannot be repaired and, if faulty or damaged, it must be replaced. The suction and liquid lines, the rubber O-rings and the A/C low
pressure switch are available for service replacement.

Refrigerant enters the accumulator canister as a low pressure vapor through the inlet tube. Any liquid, oil-laden refrigerant falls to the bottom of the
canister, which acts as a separator. A desiccant bag located inside the accumulator canister absorbs any moisture which may have entered and become
trapped within the refrigerant system.

Accumulator HVAC|Description and Operation|Page 4029 > < Wheel Fastener|Front|Page 4024