Power Transistor No. 1 Test

2. Connect the negative lead of a 1.5 volt battery to terminal # 4 of the power transistor.
3. Connect the positive lead of an ohmmeter to terminal # 13, and the negative lead of the ohmmeter to terminal # 4. There should be NO

continuity.

4. Check for continuity when the positive lead of the battery is connected to terminal # 3 of the power transistor. There should be continuity only

while the battery is connected.

Power Transistor No. 2 Test

5. Connect the negative lead of a 1.5 volt battery to terminal # 4 of the power transistor.
6. Connect the positive lead of an ohmmeter to terminal # 12, and the negative lead of the ohmmeter to terminal # 4.

Continuity should NOT exist.

7. Check for continuity when the positive lead of the battery is connected to terminal # 2 of the power transistor. Continuity should exist, while the

battery is connected.

Power Transistor No. 3 Test

8. Connect the negative lead of a 1.5 volt battery to terminal # 4 of the power transistor.
9. Connect the positive lead of an ohmmeter to terminal # 11, and the negative lead of the ohmmeter to terminal # 4. There should be NO

continuity.

10. Check for continuity when the positive lead of the battery is connected to terminal # 1 of the power transistor. There should be continuity only

while the battery is connected.

 Replace the power transistor if there is a deviation in the test results.

Component Tests and General Diagnostics|Page 5038 > < Component Tests and General Diagnostics|Page 5036