Stratus L4-2.0L VIN C (1997)
Generator: Service and Repair
REMOVAL
Remove Battery Cable At Shock Tower
1. Disconnect battery negative cable from remote negative terminal on shock tower.
2. Unplug field circuit from generator.
3. Remove B+ terminal cover by spreading the cover with a small flat blade tool.
Wiring Connections
4. Remove the B+ terminal nut and wire.
Generator
5. Loosen adjusting T-bolt, but do not remove.
6. Loosen pivot bolt, but do not remove.
7. Loosen adjusting bolt to allow removal of the generator drive belt.
8. Remove adjusting T-bolt.
9. Remove pivot bolt, do not drop spacer.