dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

MIL ON, Hex Code $3E, Sag/Hesitation/Rough Idle|Page 4106 > < MIL ON, Hex Code $3E, Sag/Hesitation/Rough Idle|Page 4100
Page 1
background image

Technical Service Bulletin # 

18-01-98

Date: 

980116

MIL ON, Hex Code $3E, Sag/Hesitation/Rough Idle

NO: 18-01-98

GROUP: Driveability

DATE: Jan. 16, 1998

SUBJECT: 
MIL Illumination with Hex Code $3E, Possible Sags/Hesitations/Rough Idle

MODELS:
1995 - 1997 (JA) Breeze/Cirrus/Stratus
1996 - 1997 (JX) Sebring Convertible

SYMPTOM/CONDITION:
MIL illumination with hex code $3E - UPSTREAM O2 SENSOR SHORTED TO VOLTAGE along with possible symptoms of sags/hesitation or rough
idle.

NOTE

HEX CODE $3E MUST BE SEEN TO PERFORM THIS REPAIR.

POLICY: Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No:

08-94-TF-91

0.4 Hrs.

FAILURE CODE:

P8 - New Part

 

Diagnosis

Using the Mopar Diagnostic System (MDS) or the Diagnostic Scan Tool (DRB III) with the appropriate Diagnostic Procedures Manual, verify all engine
systems are functioning as designed. If Diagnostic Trouble Codes (DTC's) are present, record them on the repair order and repair as necessary before
proceeding further with this bulletin. If DTC $3E is present, follow the diagnostic procedure in the applicable diagnostic manual. If no apparent reason is
found for the DTC, perform the Repair Procedure.

Parts/Equipment Required

1

CH6000

Scan Tool (DRB III)

1

CH7035

General Purpose Interface Bus Cable (GPIB)

1

CH7000/7001

J1962 Cable

AR (1)

05010885AA

Kit, Oxygen Sensor Jumper (4-cyl & 96/97 6-cyl)

AR (1)

05010934AA

Kit, Oxygen Sensor Jumper (1995 6-cyl)

AR

04778570

Heat Shrink Tubing

AR (1)

04778138

Tape, Cloth Underhood Electrical

1

NPN

Soldering Iron

1

NPN

Rosin Core Solder

Repair Procedures

This bulletin involves cutting and splicing a jumper from the oxygen sensor(s) to the powertrain control module.

Single Upstream 02 Sensor

1.

Disconnect the battery negative lead.

2.

Locate the upstream oxygen sensor connector and disconnect it.

MIL ON, Hex Code $3E, Sag/Hesitation/Rough Idle|Page 4106 > < MIL ON, Hex Code $3E, Sag/Hesitation/Rough Idle|Page 4100