background image

Fig. 12 Inlet Strainer Removal

FUEL PUMP INLET STRAINER SERVICE - REMOVAL

1. Remove fuel pump module. Refer to Fuel Pump Module Removal in this section.
2. Using a thin straight blade screwdriver, carefully pry back the locking tabs on fuel pump reservoir and remove the strainer Fig. 12.
3. Remove strainer 0-ring from the fuel pump reservoir body.
4. Remove any contaminants by washing the inside of the fuel tank.

INSTALLATION

1. Lubricate the strainer 0-ring with clean motor oil.
2. Insert strainer 0-ring into outlet of strainer so that it sits evenly on the step inside the outlet.
3. Push strainer onto the inlet of the fuel pump reservoir body. Make sure the locking tabs on the reservoir body lock over the locking tangs on the

strainer.

4. Install fuel pump module. Refer to Fuel Pump Module Installation in this section.

Fig. 14 Fuel Pump/Level Sensor Electrical Connector

FUEL LEVEL SENSOR

The fuel level sensor attaches to the side of the fuel pump module. Remove the fuel pump module to replace the fuel level sensor. Refer to Fuel
Pump Module Removal 
.