Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Testing and Inspection > < Automatic Shut Down Relay|Page 2839
Page 1
background image

Automatic Shut Down (ASD) Relay: Description and Operation
Related Trouble Code Messages & Set Conditions

Auto Shutdown Relay Control Circuit

NAME OF CODE:

Auto Shutdown Relay Control Circuit

WHEN MONITORED:

With the ignition key ON and battery voltage greater than 10 volts.

SET CONDITION:

An open or shorted condition is detected in the auto shutdown relay control circuit.

THEORY OF OPERATION:

The automatic shutdown relay (ASD) controls the 12-volt source to the fuel injectors, ignition coils, and the generator. If the vehicle is equipped
with a power distribution center (PDC), the relay will be located in the PDC. One side of the relay control coil is supplied with 12 volts when the
ignition switch is turned to the "RUN" position. The circuit is completed when the other side of the relay coil is grounded by the powertrain
control module (PCM). The PCM grounds the relay when the ignition switch is in either the RUN or CRANK position and engine RPM is
detected. If engine RPM is not detected, the PCM will remove the ASD relay control circuit ground.

POSSIBLE CAUSES:

-

Relay coil open or shorted

-

Fused ignition switch output circuit open

-

Auto shutdown relay control circuit open or shorted

-

inoperative circuit driver in powertrain control module 

No ASD Relay Output Voltage at PCM

NAME OF CODE:

No ASD Relay Output Voltage At PCM

WHEN MONITORED:

With the ignition key ON and battery voltage greater than 10 volts.

SET CONDITION:

No voltage sensed at the powertrain control module (PCM) when the auto shutdown relay (ASD) is energized.

THEORY OF OPERATION:

When the ASD relay is energized, the relay's contacts connect the fused B(+) circuit to the relay output circuit. The powertrain control module is
connected in parallel with the ASD relay output circuit. This connection provides the PCM with a circuit to monitor the ASD relay output state.
Whenever the PCM energizes the ASD relay, it checks the feedback circuit to ensure voltage is present at the ASD relay output. If voltage is not
present, a trouble code is set.

POSSIBLE CAUSES:

-

ASD relay output circuit open 

-

ASD relay

-

Fused B(+) circuit open 

-

Failed PCM

Automatic Shut Down (ASD) Relay <--> [Main Relay (Computer/Fuel System)]|Testing and Inspection > < Automatic Shut Down Relay|Page 2839