Oxygen Sensor: Service and Repair

Fig. 28 Upstream Heated Oxygen Sensor Removal/Installation

REPLACEMENT

1. Raise and support vehicle.
2. Unplug sensor connector.
3. Remove sensor using an oxygen sensor crow foot wrench such as Snap-On (TM) tool YA8875 or equivalent Fig. 28.

After removing the sensor, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap
-

If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite (R) 771-64 or equivalent. 

-

New sensors have compound on the threads and do not require an additional coating. 

-

Tighten the sensor to 28 Nm (20 ft. lbs.) torque.