Stratus L4-2.4L VIN X (1998)
Liquid Line From Expansion Valve
3. Remove liquid line at filter/drier from expansion valve.
Liquid Line From Expansion Valve
4. Remove filter/drier bracket bolt at base of filter/drier.
5. Cap liquid line and condenser threaded fitting while system is open to prevent moisture from entering system.
INSTALLATION
CAUTION: When installing new filter/drier do not leave open to atmosphere for a long period of time. The filter/drier contains moisture absorbing
materials which will absorb moisture in the atmosphere.
-
For installation, reverse the above procedures.