Procedure
Fig. 33 Auxiliary Jumper Terminal
POWERTRAIN CONTROL MODULE SERVICE
The PCM attaches to a bracket between the air cleaner housing and Power Distribution Center (PDC) Fig. 33.
REMOVAL
1. Disconnect negative cable from auxiliary jumper terminal Fig. 33.
2. Disconnect both 40-way connectors from PCM.
Fig. 34 PCM Bracket Screws
3. Remove screws attaching PCM to bracket Fig. 34.
4. Lift PCM up to remove it from vehicle.
INSTALLATION
1. Install PCM. Tighten mounting screws.
2. Attach both 40-way connectors to PCM.
3. Connect negative cable to auxiliary jumper terminal.
NOTE: Use the DRB or equivalent scan tool to reprogram the new PCM with the vehicles original identification number (VIN) and original mileage. If
this step is not done a diagnostic trouble code may be set.