Repair Procedure

This bulletin involves inspecting for leaves or other foreign material in the evaporator and HVAC housing and applying Mopar aerosol evaporator
cleaner.

NOTE

FOLLOW ALL CAUTIONS AND WARNING SUPPLIED WITH THE AEROSOL EVAPORATOR CLEANER; KEEP OUT OF REACH OF
CHILDREN; AVOID CONTACT WITH SKIN OR EYES; WEAR SKIN AND EYE PROTECTION, IF SKIN OR EYE CONTACT OCCURS,
WASH SKIN OR FLUSH EYES WITH GENEROUS AMOUNTS OF WATER; AVOID BREATHING VAPORS.

1.

Inspect the evaporator and HVAC housing for leaves or other foreign material that may be blocking the air flow through the evaporator. If the
build up is excessive replacement of the evaporator may be required.

2.

With the parking brake applied and the transmission in Park, start the engine and let idle. Put the temperature control to full hot, blower speed to
HIGH, select the PANEL and RE-CIRCULATE modes. Open all windows about 13 mm (1/2 in.). Disable the A/C compressor clutch by
disconnecting its wiring connector or the wiring connector to the A/C pressure switch.

NOTE

THIS PROCEDURE HEATS THE EVAPORATOR AND CAUSES MOISTURE TO EVAPORATE FASTER. THE SLIGHTLY OPEN
WINDOWS ALLOW MOISTURE TO ESCAPE THE VEHICLE WITHOUT LOOSING MUCH HEAT. SOMETIMES, YOU MAY SEE A
"FOG" CLOUDING THE WINDOWS. AFTER THIS "FOG" HAS DISAPPEARED CONTINUE TO OPERATE THE HEATER FOR ANOTHER
5 MINUTES. IF THE "FOG" NEVER APPEARED, OPERATE THE HEATER FOR A MINIMUM OF 30 MINUTES.

3.

Turn the ignition switch to the OFF position.

4.

Gain access to the evaporator cavity to apply the evaporator cleaner by:

AB, 1992-93 AN, GS, JA, JX, LH, NS and PL - Remove evaporator fin temperature sensor access grommet. DO NOT REMOVE THE PROBE
FROM THE EVAPORATOR.

BR, TJ, XJ, ZG, ZJ - Remove blower resistor.

For the above vehicles, place a piece of heavy masking tape over the opening in the evaporator housing where the fin temperature sensor access
grommet or blower resistor was removed, then punch a small hole for the evaporator cleaner tube to be inserted into.

AA, AC, AG, AJ, AP, and AY - Remove the screw attaching the right side floor duct. Use an 1/8 in. drill bit to drill through the bottom of the
screw hole, Figure 1.