Stratus V6-2.5L VIN H (1997)
Fig 53 Liquid Line From Expansion Valve
3. Remove liquid line at filter/drier from expansion valve.
Fig 54 Receiver/Drier Bracket
4. Remove filter/drier bracket bolt at base of filter/drier.
5. Cap liquid line and condenser threaded fitting while system is open to prevent moisture from entering system.
CAUTION: When installing new filter/drier do not leave open to atmosphere for a long period of time. The filter/drier contains moisture absorbing
materials which will absorb moisture in the atmosphere.
INSTALLATION
For installation, reverse the above procedures.