dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Connecting Rod and Bearing Fitting|Page 1304 > < Connecting Rod Bearing|Specifications|Page 1301
Page 1
background image

Connecting Rod Bearing: Service and Repair
Connecting Rod and Bearing Fitting

CONNECTING ROD FITTING 

1. For measuring connecting rod bearing clearance procedure and use of Plastigage. For bearing clearance refer to Specifications.

NOTE:  The rod bearing bolts should not be reused.

2. Before installing the NEW bolts the threads should be oiled with clean engine oil.
3. Install each bolt finger tight then alternately torque each bolt to assemble the cap properly.
4. Tighten the connecting rod bolts using the 2 step torque-turn method. Tighten according to the following values:

CAUTION:  Do not use a torque wrench for the second step.

1. Tighten the bolts to 27 Nm (20 ft. lbs.).
2. Tighten the connecting rod bolts an additional 1/4 TURN.

5. Using a feeler gauge, check connecting rod side clearance (Fig. 61). 

Connecting Rod and Bearing Fitting|Page 1304 > < Connecting Rod Bearing|Specifications|Page 1301