dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 646
Page 1
background image

Evaporator Temperature Sensor / Switch: Service and Repair

REMOVAL 

1. Disconnect negative battery cable.

2. Remove the blower motor. See: Heating and Air Conditioning/Blower Motor/Service and Repair

3. Remove resistor card from underside of HVAC. See: Heating and Air Conditioning/Blower Motor Resistor/Service and Repair

4. Lower the glove box door.

Fig.17 Evaporator Probe

5. Reach through the glove compartment door opening and disconnect the evaporator temperature sensor wiring connector.

6. Using a flat blade pry tool, pull back on the locking tab. Twist access plate clockwise one-quarter turn and pushed inside the A/C housing. Then

orientated the plate in such a way that it can be removed from the housing.

7. Using the access plate hole in the housing as a view hole, reach hand up through blower opening to pull the evaporator probe from the evaporator

coil.

INSTALLATION 

1. Install new sensor into the evaporator.

NOTE:  The evaporator is manufactured with three holes for probe insertion. Insert the probe in the uppermost hole.

2. Using the access plate hole in the housing as a view hole, reach up through blower opening to install the evaporator probe to the evaporator coil.
3. Replace access plate to HVAC housing.
4. Reach through the glove compartment door opening and connect the evaporator temperature sensor wiring connector.
5. Install glove compartment door.

6. Install the resistor card to the underside of the HVAC. See: Heating and Air Conditioning/Blower Motor Resistor/Service and Repair

7. Install the blower motor. See: Heating and Air Conditioning/Blower Motor/Service and Repair

8. Connect negative battery cable.

Refrigerant Pressure Sensor / Switch, HVAC > < Component Locations|Page 646