dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Leak Detection Pump, Evaporative System|Locations|Page 3160 > < Leak Detection Pump, Evaporative System|Locations|Page 3158
Page 3
background image

Figure 4

Diaphragm Upward Movement
When the PCM energizes the LDP solenoid, the solenoid blocks the atmospheric port leading through the EVAP air filter and at the same time
opens the engine vacuum port to the pump cavity above the diaphragm. The diaphragm moves upward when the vacuum above the diaphragm
exceeds spring force. This upward movement closes the vent valve. It also causes low pressure below the diaphragm, unseating the inlet check
valve and allowing air in from the EVAP air filter. When the diaphragm completes its upward movement, the LDP reed switch turns from
closed to open .

Figure 5

Diaphragm Downward Movement
Based on reed switch input, the PCM deenergizes the LDP solenoid, causing it to block the vacuum port, and open the atmospheric port. This
connects the upper pump cavity to atmosphere through the EVAP air filter. The spring is now able to push the diaphragm down. The
downward movement of the diaphragm closes the inlet check valve and opens the outlet check valve pumping air into the evaporative system.
The LDP reed switch turns from open to closed, allowing the PCM to monitor LDP pumping (diaphragm up/down) activity. During the
pumping mode, the diaphragm will not move down far enough to open the vent valve.

The pumping cycle is repeated as the solenoid is turned ON and OFF. When the evaporative system begins to pressurize, the pressure on the
bottom of the diaphragm will begin to oppose the spring pressure, slowing the pumping action. The PCM watches the time from when the
solenoid is de-energized, until the diaphragm drops down far enough for the reed switch to change from open to closed. If the reed switch
changes too quickly, a leak may be indicated. The longer it takes the reed switch to change state, the tighter the evaporative system is sealed. If
the system pressurizes too quickly, a restriction somewhere in the EVAP system may be indicated.

Pumping Action
During portions of this test, the PCM uses the reed switch to monitor diaphragm movement. The solenoid is only turned on by the PCM after
the reed switch changes from open to closed, indicating that the diaphragm has moved down. At other times during the test, the PCM will
rapidly cycle the LDP solenoid on and off to quickly pressurize the system. During rapid cycling, the diaphragm will not move enough to
change the reed switch state. In the state of rapid cycling, the PCM will use a fixed time interval to cycle the solenoid.

Leak Detection Pump, Evaporative System|Locations|Page 3160 > < Leak Detection Pump, Evaporative System|Locations|Page 3158