dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Housing Assembly HVAC > < Handling Tubing and Fittings|Page 4131
Page 1
background image

Hose/Line HVAC: Service and Repair
A/C Suction Hose/Line Replacement

Fig 45  Actuator Lines

REMOVAL

1. Remove refrigerant from the A/C system using a refrigerant recovery machine.
2. Remove suction line bolt and line from A/C compressor.

Fig 34  Dual Pressure Switch

3. Remove suction line bolt and line from evaporator.
4. Raise vehicle on a hoist.
5. Remove the two suction line strap attaching screws.

CAUTION:  Cap all lines that are not being replaced and cap the expansion valve tubes.

6. Remove suction line from vehicle raise or lower vehicle as necessary

INSTALLATION

For installation, reverse the above procedures. 
-

Tighten Suction Line bolt at the Compressor to 20 to 30 Nm (15 to 22 ft. lbs.) torque.

-

Tighten the Suction Line at the Evaporator to 30 to 35 Nm (22 to 26 ft. lbs.) torque.

Housing Assembly HVAC > < Handling Tubing and Fittings|Page 4131