Viper SRT-10 V10-8.4L (2008)
5. Pull out the locking wedge.
6. Using a small screwdriver lift locking finger (1) away from terminal (2) and push terminal out of connector. Remove the fuel level sensor signal
and ground terminals out of the connector.
Installation
INSTALLATION
CAUTION: Handle the fuel level sensor with extreme care while installing to the fuel pump module housing. The sensor is very fragile and can
be damaged very easily if the float is allowed to move and fall back onto itself. A inaccurate gauge reading or no reading at all may result.
CAUTION: Make sure the signal and ground wires are installed in the correct position. Make sure each electrical terminal (2) is locked into
position by the locking finger (1).
1. Push the fuel level sensor electrical terminal up into bottom of fuel pump/level sensor connector. Install the fuel level sensor signal and ground
terminals to the connector.
2. Install locking wedge on connector.