Pick-Up Coil: Adjustments

Air Gap Adjustment On Single Pick-Up Distributor

SINGLE PICK-UP DISTRIBUTOR

1.

Align one reluctor tooth with pick-up coil tooth.

2.

Loosen pick-up coil hold down screw

3.

Insert .006" (0.15mm) non-magnetic feeler gauge between reluctor tooth and pick-up coil tooth.

4.

Adjust air gap so that contact is made between reluctor tooth and pick-up coil tooth.

5.

Tighten hold down screw.

6.

Remove feeler gauge. No force should be required in removing feeler gauge.

7.

Check air gap with .008" (0.20mm) feeler gauge. A .008" (0.20mm) feeler gauge should fit into air gap.
CAUTION:  A .008" (0.20mm) feeler gauge can be forced into air gap. Do not force feeler gauge into air gap.

Air Gap Adjustment On Dual Pick-Up Distributor

DUAL PICK-UP DISTRIBUTOR

NOTE:  In dual pick-up distributors start pickup is identified by two prong male connector. The run pick-up is identified by a male and female
plug.

START PICK-UP

1.

Align one reluctor tooth with pick-up coil tooth. 

2.

Loosen pick-up coil hold down screw.

3.

Insert .006" (0.15mm) nonmagnetic feeler gauge between reluctor tooth and pick-up coil tooth.

4.

Adjust air gap so that contact is made between reluctor tooth, feeler gauge, and pick-up coil tooth.

5.

Tighten hold down screw.

6.

Remove feeler gauge. No force should be required in removing feeler gauge.

Pick-Up Coil, Ignition|Specifications|Page 2238 > < Pick-Up Coil, Ignition|Specifications|Page 2236