W350 1 Ton Pickup 4WD V8-360 5.9L VIN 1 4-bbl (1988)
Pick-Up Coil: Adjustments
Air Gap Adjustment On Single Pick-Up Distributor
SINGLE PICK-UP DISTRIBUTOR
1.
Align one reluctor tooth with pick-up coil tooth.
2.
Loosen pick-up coil hold down screw
3.
Insert .006" (0.15mm) non-magnetic feeler gauge between reluctor tooth and pick-up coil tooth.
4.
Adjust air gap so that contact is made between reluctor tooth and pick-up coil tooth.
5.
Tighten hold down screw.
6.
Remove feeler gauge. No force should be required in removing feeler gauge.
7.
Check air gap with .008" (0.20mm) feeler gauge. A .008" (0.20mm) feeler gauge should fit into air gap.
CAUTION: A .008" (0.20mm) feeler gauge can be forced into air gap. Do not force feeler gauge into air gap.
Air Gap Adjustment On Dual Pick-Up Distributor
DUAL PICK-UP DISTRIBUTOR
NOTE: In dual pick-up distributors start pickup is identified by two prong male connector. The run pick-up is identified by a male and female
plug.
START PICK-UP
1.
Align one reluctor tooth with pick-up coil tooth.
2.
Loosen pick-up coil hold down screw.
3.
Insert .006" (0.15mm) nonmagnetic feeler gauge between reluctor tooth and pick-up coil tooth.
4.
Adjust air gap so that contact is made between reluctor tooth, feeler gauge, and pick-up coil tooth.
5.
Tighten hold down screw.
6.
Remove feeler gauge. No force should be required in removing feeler gauge.