Blower Motor: Service and Repair

1. Disconnect battery ground cable.
2. Working in engine compartment, disconnect blower motor wire.
3. Remove three retaining nuts for blower scroll cover to which blower assembly is attached and remove blower motor and fan.
4. Reverse procedure to install.