Mixture Control (MC) Solenoid: Testing and Inspection

1.

Using jumper wires, connect one terminal of solenoid wire connector to positive terminal of 12V battery.

2.

Connect other terminal of connector to negative terminal.

3.

Remove rubber seal and retainer from end of solenoid stem and attach hose from hand vacuum pump.

4.

With solenoid energized (lean position), apply 25 inches Hg of vacuum and time rate of leak down from 20 inches Hg to 15 inches Hg. Leak down
should not exceed 5 inches Hg in 5 seconds, if so replace solenoid.

5.

Check solenoid for sticking in down position by disconnecting jumper wire and checking that vacuum gauge pointer moves to zero in less than one
second.