Medallion L4-2165cc 2.2L (1988)
FIGURE 13
5.
Locate the green wire [mounted on the ECU clamshell (N)] leading to terminal "C" of the map sensor connector (M). See Fig. 13
6.
Remove the heat shrink tubing that is covering a connection approximately 1-1/2 inches from the connector.
FIGURE 12
7.
Unsolder the voltage source wire (E) and remove from the green map sensor feed wires. Discard the oxygen sensor module kit. See Fig. 12.
8.
Slide a length of heat shrink tubing over the green wire.
9.
Resolder the two ends of the green wire together.
10.
Slide the heat shrink tubing over the soldered connection, being sure that the tubing completely covers the soldered joint and any section of bare
wires.
FIGURE 14
11.
Shrink the tubing with a heat gun (R). See Fig. 14.
12.
Position the ECU black plastic cover and secure with wing nut.