eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Fixed Orifice - Service Procedure, Manual Revision|Page 2671 > < Fixed Orifice - Service Procedure, Manual Revision|Page 2669
Page 4
background image

Figure 3

This procedure involves removing the A/C fixed orifice, removing a section of the fixed orifice line, and installing filter assembly.

1.

Disconnect battery negative cable.

2.

Discharge the refrigerant system as described on page 24-44 in the 1990 Premier/Monaco Service Manual.

3.

Disconnect the lower line (fixed orifice line) at the condenser. Figure 3.

Figure 4

4.

Insert fixed orifice removal tool 6146 from A/C Compressor Tool Kit 6125 (MS.1979) into the fixed orifice line. Figure 4.

5.

Turn the tool clockwise to engage tabs on the fixed orifice tube.

6.

Remove the fixed orifice and discard it.

Fixed Orifice - Service Procedure, Manual Revision|Page 2671 > < Fixed Orifice - Service Procedure, Manual Revision|Page 2669