eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Heater Core > < Fixed Orifice - Service Procedure, Manual Revision|Page 2671
Page 6
background image

NOTE:

ORIENTATION OF THE ORIFICE FILTER IS IMPORTANT. BE SURE THE FILTER IS INSTALLED IN THE
DIRECTION INDICATED ON THE FILTER LABEL. THE LONG STEM ON THE FILTER HOUSES THE FIXED
ORIFICE AND MUST BE INSTALLED IN THE HOSE END CLOSEST TO THE EVAPORATOR.

11.

Tighten the clarups to 45 inch pounds (5 N-m).

12.

Install the battery negative cable.

13.

Evacuate and charge the A/C system as described on pages 24-45 and 46 in the 1990 Premier/Monaco Service Manual.

POLICY:

Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:
Labor Operation No. 24-35-21-90 . . . . . . . . . . . . 0.8 Hrs.

FAILURE CODE: 41 - Foreign material

Heater Core > < Fixed Orifice - Service Procedure, Manual Revision|Page 2671