eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Relays and Modules - Computers and Control Systems > < Diagram Information and Instructions|Page 1555
Page 1
background image

Oxygen Sensor: Service and Repair

1. Disconnect oxygen sensor electrical connector.
2. Using a 7/8 inch crowfoot or equivalent, remove sensor from exhaust manifold.
3. Clean exhaust manifold threads.
4. Reverse procedure to install. Torque sensor to 22 ft. lbs. If original sensor is to be reinstalled, coat threads with a suitable anti-seize

compound. 