MFI Relay Inspection

4. Check the voltage at MFI relay terminal (1) while connecting and disconnecting the jumper lead at the battery (-)terminal.

MFI Relay Inspection

5. Use the jumper leads to connect MFI relay terminal (8) to the battery (+) terminal and terminal D6 to the battery (-) terminal.

MFI Relay Inspection

6. Check the continuity between MFI relay terminals (2) - (4) and terminals (3) - (4) while connecting and disconnecting the jumper lead at the

battery (-) terminal.

7. If there is a defect, replace the MFI relay.