Summit L4-1795cc 1.8L SOHC (1995)
Canister Purge Solenoid: Initial Inspection and Diagnostic Overview
Harness Inspection
Step 1
Step 2
Solenoid Inspection
1. Disconnect and mark the black and red-striped vacuum hoses from the solenoid.
2. Disconnect the electrical connector.
Fig. 16 Testing Purge Control Solenoid Valve
3. Connect a hand vacuum pump to the port that the red-striped hose was disconnected and apply vacuum.
Fig. 1 Purge Control Solenoid Valve Inspection (Operation)
4. Check for vacuum leak to opposite port when voltage is supplied and not supplied as per Fig. 1