eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4350 > < Diagram Information and Instructions|Page 4347
Page 1
background image

Canister Purge Solenoid: Initial Inspection and Diagnostic Overview

Harness Inspection

Step 1

Step 2

Solenoid Inspection

1. Disconnect and mark the black and red-striped vacuum hoses from the solenoid.
2. Disconnect the electrical connector.

Fig. 16  Testing Purge Control Solenoid Valve

3. Connect a hand vacuum pump to the port that the red-striped hose was disconnected and apply vacuum.

Fig. 1 Purge Control Solenoid Valve Inspection (Operation)

4. Check for vacuum leak to opposite port when voltage is supplied and not supplied as per Fig. 1

Initial Inspection and Diagnostic Overview|Page 4350 > < Diagram Information and Instructions|Page 4347