Summit Vista AWD L4-1795cc 1.8L SOHC (1992)
Insert the probe from the wire side of the connector, and compare the measured voltage to the corresponding pin on the chart.
NOTE:
^
Measure voltages with engine control unit connectors connected.
^
Use the ground pin (terminal # 26 on 1.8L, terminal # 106 on 2.4L) as the ground for the voltmeter.
If voltage measured differs from that listed on the chart, check the corresponding sensor, actuator, or related electrical circuit. After repairs have
been completed, recheck voltmeter readings to confirm that the repair has corrected the problem.