Power Door Lock Actuator: Testing and Inspection
Front Door

FRONT DOOR LOCK ACTUATOR INSPECTION (LH)

1. After setting the rod to the LOCK position, apply the battery voltage to terminal 1 and check if the rod moves to the UNLOCK position when

terminal 3 is grounded.

2. After setting the rod to the UNLOCK position and applying battery voltage to terminal 3, check if the rod moves to the LOCK position when

terminal I is grounded.

3. When the actuator rod is set to the UNLOCK position, check if there is continuity between terminal 2 and terminal 4, and when the rod is set to the

LOCK position, check if there is no continuity.

FRONT DOOR LOCK ACTUATOR INSPECTION (RH)

1. After setting the rod to the LOCK position and applying battery voltage to terminal 3, check if the rod moves to the UNLOCK position when

terminal 1 is grounded.

2. After setting the rod to the UNLOCK position and applying battery voltage to terminal 1, check if the rod moves to the LOCK position when

terminal 3 is grounded.

3. When the actuator rod is set to the UNLOCK position, check if there is continuity between terminal 2 and terminal 4, and when the rod is set to the

LOCK position, check if there is no continuity.