eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 2603 > < Diagram Information and Instructions|Page 2601
Page 3
background image

Continuity:  Should exist 

4. Connect a volt meter to oxygen harness connector terminal A3.
5. Start engine and measure voltage at idle.

Voltage:  System Voltage. 

NOTE:  After warm-up, No voltage will be present.

5. Raise engine speed to 5000 RPM and measure voltage.

Voltage:  0 Volts. 

Osciloscope Test

OSCILLOSCOPE TEST

1.  Connect scope pickup probe to the sensor terminal A1. 
2. Warm engine to operating temperature and keep it running at 2,000 RPM, check the waveform on the scope. If scope pattern is not as depicted in

image,  the sensor may be bad or there could be a fuel mixture problem. Refer to Computers and Control Systems/System Diagnosis/Diagnosis
by Symptom
 for further system troubleshooting before replacing the assembly.  See: Computers and Control Systems/Testing and
Inspection/Symptom Related Diagnostic Procedures

HARNESS TEST

Oxygen Sensor

Diagram Information and Instructions|Page 2603 > < Diagram Information and Instructions|Page 2601