eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Relays and Modules - Windows and Glass > < Heated Glass Element Relay|Locations|Page 7849
Page 1
background image

Heated Glass Element Switch: Testing and Inspection

Rear Window Defogger Switch Inspection

Rear Window Defogger Switch Inspection Continuity Chart

1.

Remove the meter hood from the instrument panel.

2.

Operate the switch and check for continuity between the terminals.

3.

Apply battery voltage between the terminals 3, 4 and 2 to confirm that the test light illuminates for about 11 minutes when the switch is turned on.