Radiator Cooling Fan Motor: Testing and Inspection
Radiator Fan Motor Circuit Test

1. Run engine to normal operating temperature.

2. Check wiring connector in C25, C9 and C26 for proper engagement.

3. Connect diagnostic read out tool DRB II to diagnostic connector. Check for fault codes.

4. If fault code 88,12,35,55 is detected, proceed with next step.

5. With ignition switch in Run position, test for battery voltage at fan relay single pin connector. If battery voltage is detected or if voltage reads at

zero to one volt, proceed with next step.

6. With ignition switch in Off position, disconnect the 60-way connector from engine controller and return ignition switch to Run position, then

proceed as follows:

 Engine Controller 60-way Connector.

a. Test for battery voltage at terminal 31 of 60-way connector. 

7. If battery voltage exists and female terminal is not damaged, replace engine controller. If no battery voltage exists, repair open or short in circuit

C27.

8. With ignition switch in Off position, disconnect 60-way connector from engine controller and return ignition switch to Run position. Test for

battery voltage at single pin connector on fan relay. If battery voltage exists, replace engine controller. If voltage is zero to one volt proceed to last
step.

9. With ignition switch in Run position, test for battery voltage at wire C27 in 3-way connector of fan relay. If battery voltage exists, replace fan

relay. If voltage is zero to one, repair open or short in circuit C27.

10. Turn ignition switch Off, connect 60-way connector and test system.

Condenser Fan Motor Test|Page 1881 > < Condenser Fan Motor Test|Page 1879