8. If the sensor is defective, replace the heated oxygen sensor (front).

NOTE: For removal and installation of the heated oxygen sensor (front), refer to Service and Repair.

HEATED OXYGEN SENSOR (REAR)

1. Disconnect the heated oxygen sensor (rear) connector.
2. Make sure that there is continuity [Approx. 20 Ohms at 20°C (68°F)] between terminals G3 and terminal D4 on the heated oxygen sensor (rear)

connector.

3. If there is no continuity, replace the heated oxygen sensor (rear).

NOTE:  If the scan tool does not display the standard value although no abnormality is found by the above mentioned continuity test and harness check,
replace the heated oxygen sensor (rear).

With Federal or Canada Emissions

Step 1

Step 2