background image

Air Door Cable: Technical Service Bulletins
Heater Control Cable - Adjustment Procedure

NO.: 24-51-91

GROUP:

HEATER & A/C

DATE:

Oct. 21, 1991

SUBJECT:  Heater Control Cable Adjustment Procedure - Service Manual Supplement

MODELS:

1991 

(B2) SUMMIT 
(BD) TALON

Figure 1

DISCUSSION:

Adjustment procedures have been developed for adjusting the inside/outside air changeover cable on the listed models.  This procedure pertains to the
Summit and Talon models. This information is not in the 1991 Service Manuals but should be noted for future reference in each of the applicable 1991
Service Manuals.

SUMMIT AND TALON MODELS

1.

Set the inside/outside air control knob or lever to the inside air circulation position.

2.

Move the inside/outside air control damper lever in the direction of the arrow until it contacts the stop (Figure 1).

3.

Connect the inner wire of the inside/outside air control cable to the damper lever.

4.

While pulling the outer cable of the inside/outside air changeover cable lightly toward the heater control assembly, insert the outer cable in the
clamp and secure.

5.

After operating the inside/outside control knob or lever two to three times, set it to the inside air circulation position. When doing this, make sure
that the damper lever is in contact with the stop. If the damper level is not in contact with the stop, repeat the adjustment.

6.

Set the inside/outside air changeover lever to the inside air circulation position to make sure that the pin of the damper lever is within the range B
shown in the illustration.  If the pin is not within the range B, repeat the adjustment procedure.