Evaporative Check Valve: Testing and Inspection

Attach a clean hose and check the operation of the fuel tank pressure relief valve.

Inspection procedure

Normal condition

Lightly blow from inlet side

Air passes through with a

(fuel tank side)

slight feeling of resistance

Lightly blow from outlet side

Air passes through