eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Shifter A/T > < Shift Solenoid, A/T|Specifications
Page 1
background image

Shift Solenoid: Testing and Inspection

SHIFT CONTROL SOLENOID VALVE A (SCSV-A) CHECK

1. Disconnect the SCSV-A connector.
2. Measure the resistance between the SCSV-A side connector terminal 3 and the body ground.

Standard value: approximately 22 ohms [at 20° C (68° F)]

3. If the resistance is outside the standard value, replace the solenoid valve assembly.

SHIFT CONTROL SOLENOID VALVE B (SCSV-B) CHECK

1. Disconnect the SCSV-B connector.
2. Measure the resistance between the SCSV-B side connector terminal 4 and the body ground.

Standard value: approximately 22 ohms [at 20° C (68° F)]

3. If the resistance is outside the standard value, replace the solenoid valve assembly.

Shifter A/T > < Shift Solenoid, A/T|Specifications