Keyless Entry Transmitter: Service and Repair

The content of this article reflects the changes called out by TSB 26-06-95.

HOW TO REGISTER A SECRET CODE

Since the transmitter is memorized by each individual code, it is necessary to register a code on EEPROM in the control unit if the transmitter or
control unit is replaced, or cause of the trouble is presumed to be due to faulty registration of the code. Since two different codes at the most can be
memorized in the memory space of the EEPROM, the old code will become unable to be used if the following registration operation is repeated twice.
Meanwhile, register a code after confirming that an ordinary door lock function can be worked through key operation.

1. Close both doors.

2. Jumper pin # 1 pin # 4 of the data link connector.
3. Turn the ignition switch to ACC and return it to OFF.

Note: This locks and unlocks the door once, and then a code can be registered.

4. Press any button on the transmitter. Press it three times within 10 seconds to register transmitter 1.
5. After registration is complete, the door will be locked and unlocked once.

Note: If there are two transmitters, the second transmitter can be programmed by pressing any button on the second transmitter 3 times within 10

seconds. This will register the second code. The second transmitter programming function must be performed within 60 seconds of the first
programming.

6. After the second registration is completed, the door will be locked and unlocked once.
7. Registration mode finishes under the following conditions.

-

Registration of two transmitter codes are completed.

-

One minute has passed since the registration mode setting.

-

Jumper between pin # 1 and # 4 of data link connector is disconnected.

-

Ignition switch is turned ON.

-

Any of the doors are opened.