Talon FWD L4-1997cc 2.0L DOHC Turbo VIN F SMFI (1998)
C. O-Ring Installation
Insert the O-ring to the water inlet pipe, and coat the outer inside diameter of the O-ring with water or engine coolant.
CAUTION: Do not let engine oil or other greases contact with the O-ring.
D. Thermostat Case Assembly Installation.
1. Loosen the water inlet pipe bolt shown in the illustration.
2. Apply specified sealant to the thermostat case assembly in the places shown in the illustration.
Specified sealant: MITSUBISHI GENUINE PART MD970389 or equivalent
3. Apply a small amount of water to the O-ring of the water inlet pipe, and then press the thermostat case assembly into the water inlet pipe.
4. Tighten the thermostat case assembly mounting bolts.
5. Tighten the water inlet pipe bolts.
E. Radiator Lower Hose/ Radiator Upper Hose Connection.
1. Insert each hose as far as the projection of the water outlet fitting or water inlet fitting.