Step 8 --- Heater Unit Removal
After Sliding the cooling unit towards you slightly, and then remove the heater unit.

INSTALLATION

For installation reverse steps in image and note the following:

Step 7 --- Clip Installation
1. With the pin pulled out, insert the clip into the hole.
2. Push the pin inward until the pin's head is flush with the grommet.

High Pressure Safety Valve HVAC > < Heater Core|Service and Repair