eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Relays and Modules - Fuel Delivery and Air Induction > < Automatic Shut Down (ASD) Relay|Page 1809
Page 1
background image

Main Relay (Computer/Fuel System): Testing and Inspection

1. Remove the relay.
2. Check that there is continuity between terminals 4 and 6.

Standard value: 35 - 75 ohms

3. Use jumper leads to connect relay terminal No. 6 to the battery (+) terminal and terminal No. 4 to the battery (-) terminal. Check the continuity

between relay terminal Nos. 2 - 8 while connecting and disconnecting the jumper lead at the battery (-) terminal.

Jumper lead

Continuity between terminal

Nos. 2 - 8

Connected

Continuity (0 ohms)

Disconnected

No continuity (infinite ohms)

4. If there is a defect, replace the multiport fuel injection relay.

Relays and Modules - Fuel Delivery and Air Induction > < Automatic Shut Down (ASD) Relay|Page 1809