Refrigerant Pressure Sensor / Switch: Testing and Inspection

Dual Pressure Switch Test

Dual Pressure Switch Test

1. Remove the dual pressure switch connector and connect the high/low pressure side terminals located on the harness side as shown in the

illustration.

2. Install a gauge manifold to the high-pressure side service valve of the refrigerant line. (Refer to Performance Test.)  See: Heating and Air

Conditioning/Testing and Inspection

3. When the high/low pressure sides of the dual pressure switch are at operating pressure (ON) and there is continuity between the respective

terminals, then the condition is normal. If there is no continuity, replace the switch.

Switch Position OFF to ON
-

Low-pressure side kPa (psi) 220 (32)

-

High-pressure side kPa (psi) 2,550 (370)

Switch Position ON to OFF
-

Low-pressure side kPa (psi) 2OO (29)

-

High-pressure side kPa (psi) 3,140 (456)