eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

With Antilock Brakes|Page 5297 > < Self Centering Combination Valve|Page 5294
Page 1
background image

Brake Proportioning/Combination Valve: Testing and Inspection
With Antilock Brakes

Fig. 37 Proportioning Valve Pressure Test Connections

On vehicles with Teves Mark IV ABS system refer to "Anti-Lock Brakes" section for "Testing" procedures.

All ABS components use an ISO type tubing flare. Ensure proper adapters with ISO type flare are used when installing test gauges.

1.

Install one gauge of set No. C-700A or equivalent, between hydraulic assembly and male end (inlet) of valve.

2.

Install second gauge of set No. C-700A or equivalent at female end (outlet) of valve.

3.

While watching inlet and outlet pressure gauges, have an assistant depress the brake pedal. Note gauge readings, then refer to "Hydraulic Brake
Controls Specifications" chart.

4.

If pressures are not within specifications replace proportioning valve.

With Antilock Brakes|Page 5297 > < Self Centering Combination Valve|Page 5294