eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Service Port HVAC|Locations
Page 1
background image

Service Port HVAC: Service and Repair

REMOVAL

1. Remove the valve caps. Remove refrigerant from A/C system using a refrigerant recovery machine.
2. Using a standard valve core tool, remove the valve core. Be careful to prevent any dirt/debris from entering the valve core opening or getting on

the replacement valve core.

3. When assembling the new valve core into the manifold, the core should be oiled with clean ND8 PAG compressor oil.

CAUTION:  A valve that is not fully seated can lead to damage to the valve during evacuation and charge. This can result in system refrigerant
discharge while uncoupling the charge adapters.

INSTALLATION

1. Install valve core into manifold. Torque to 30 N.m (22 ft. lbs.).
2. Evacuate and charge the A/C system.

Solar Sensor, HVAC > < Service Port HVAC|Locations