Vision V6-215 3.5L SOHC (1995)
Fuel Line Quick Connect Fitting
3. Push fitting over fuel tube until retainer seats and a click is heard. When the fitting is properly locked disconnect tool should be in the out position.
4. Verify connection by pulling on the fuel tube. If fitting locks in place connection is secure.
5. Using the DRB II select the Automatic Shut Down (ASD) Fuel System Test to pressurize fuel system and check for leaks. SEE COMPUTERS
AND CONTROL SYSTEMS/SCAN TOOL ORIENTATION.
CAUTION: Unless the test is stopped or the ignition switch is turned to the OFF position the fuel pump relay and the ASD relay will remain energized
for 7 minutes by the ASD Fuel System Test.
Retainer Ring Type Fittings
NOTE: Plastic ring type quick connect fittings are not serviced separately. Do not attempt to repair damaged quick connect fittings or tubes. Replace
complete fuel tube/quick connect fitting assembly.
REMOVAL
Fuel Line Quick Connect Fitting