Page 27
background image

15.

23.

Install the locking wedge into the "Jumper B" electrical connector.

24.

On manual transmission equipped vehicles, reposition the brake shift lock solenoid electrical connector within the wiring harness and rewrap the
harness with electrical tape.

25.

On automatic transmission equipped vehicles, connect the electrical connector to the brake shift lock solenoid.

26.

Install the ignition switch electrical connector. Tighten the retaining screw securely.

27.

Connect the relay harness to the three (3) open electrical connectors. Connector halves will only mate with their correct opposite halves. See
Figure 16.

Recall - Accessory Power Circuit Relay Installation|Page 3934 > < Recall - Accessory Power Circuit Relay Installation|Page 3932