OPERATION 

The zirconium dioxide in the sensor is electrically sensitive to differences in the amount of oxygen present between two sources. The outside of
the sensor is vented to the atmosphere while the inside is exposed to the exhaust stream. The differing amounts of oxygen present between the two
sources causes the sensor to generate a voltage.

A rich fuel mixture will result in a low level of oxygen present in the exhaust. This will produce a larger difference in oxygen levels sensed by the
HO2S which will result in a higher voltage being produced.

A lean fuel mixture will result in a high level of oxygen present in the exhaust. This will produce a smaller difference in oxygen levels sensed by
the HO2S which will result in a lower voltage being produced.

Normal operating range for the HO2S is 0.0 volts (lean condition) to 1.1 volts (rich condition).

The HO2S temperature must be above 600°F to operate properly. To minimize heat up time, a heating element is incorporated into the sensor.

Heated Oxygen Sensor

The HO2S uses a 4 wire connection.

- HO2S wire is the sensor output.

- SIG RTN is the sensor ground.

- 12.0 volt power supply for the sensor heater, from the Ignition Run circuit.

- Ground wire for the sensor heater.