Condenser HVAC: Service and Repair

Fig. 2 Spring lock coupling disconnect & connect

1.

Discharge refrigerant from system.

2.

Disconnect and cap compressor discharge line and liquid line from condenser, Fig. 2.

3.

Remove upper radiator brackets and tilt top of radiator rearward. Then remove two bolts attaching two condenser upper mounting brackets to rear
side of radiator support.

4.

Remove condenser from vehicle.

5.

Reverse procedure to install. Use new O-ring lubricated with suitable oil.

6.

Leak test, evacuate and charge system. 