ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Evaporative Check Valve|Specifications|Page 1715 > < Canister Purge Solenoid|Locations|Page 1711
Page 1
background image

Evaporative Check Valve: Specifications

EGR VALVE 

Vacuum To open ..................................................................................................................................................................  65 mm Hg (2.59 in Hg) 
Minimum coolant temperature  .............................................................................................................................................................  55°C (131°F) 

ROLLOVER/VENT VALVE 

Tank pressure to open (max.) ...........................................................................................................................................................  7.0 kPa (1.0 psi) 
Air pressure to vent tank (max.) .......................................................................................................................................................  4.9 kPa (0.7 psi) 

TWO-WAY CHECK VALVE 

Vacuum To open port A .......................................................................................................................................................  26 mm Hg (1.01 in Hg) 
Vacuum To open port B .......................................................................................................................................................  44 mm Hg (1.73 in Hg) 

Evaporative Check Valve|Specifications|Page 1715 > < Canister Purge Solenoid|Locations|Page 1711