ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Heater Core - A Moan or Buzzing Sound|Page 1969 > < Heater Core - A Moan or Buzzing Sound
Page 1
background image

Heater Core: All Technical Service Bulletins
Heater Core - A Moan or Buzzing Sound

Article No. 86-10-16

NOISE - MOAN - HEATER CORE (2.9L ENGINE)

LIGHT TRUCK 1986 RANGER, BRONCO II

A moan or buzzing sound may be emitted from the heater core area during engine operation. The engine speed for noise occurence varies between
vehicles. The moan sound is a fluid flow induced vibration in the heater core.

Perform the following diagnostic testing to verify the cause of the complaint, If the testing indicates a heater core moan, add one stop leak pellet
(E6AZ-19558-A) to the radiator to correct the moan condition.

Diagnostic Test Procedure

1.

Start the engine and accelerate to approximately 3500 rpm to verify the heater core moan condition.

2.

If a heater core moan sound occurs, stop the coolant flow by clamping the heater core inlet hose with a "C" clamp or locking pliers applied with
protective pads.

a.

If the heater core moan sound does not stop after stopping the coolant flow, refer to the Noise, Vibration and Harshness (NVH) Diagnosis
located in the Shop Manual.

b.

If the moan sound is stopped by clamping the heater inlet hose, stop the engine, remove the clamp and proceed to Step C.

c.

Add one stop leak pellet (part number E6AZ- 19558-A) to the radiator to correct the moan condition.

NOTE:

Tests indicate that using restrictors or pinching off the heater hoses does not stop the moan from occuring and could affect heater warm-up
performance.
PART NUMBER

PART NAME

CLASS

E6AZ-19558-A

Pellet - Stop Leak

A

OTHER APPLICABLE ARTICLES: None
WARRANTYSTATUS: Reimbursable within the provisions of the Warranty and Policy Manual.
OPERATION: SP18476A86
TIME:

0.3 Hr. DLR. CODING: Basic Part No. 18476 - Code: 56