Contour L4-122 2.0L CNG DOHC VIN Z SFI (1996)
^
The VCL module is attached with Velcro strips. Gently remove the VCL module down from the duct area.
^
Insert the V1-255 program card into the NGS tester.
^
Using cable K1-124 (supplied in kit), insert one end of the cable into the RS-232 and V PWR-OUT ports of the NGS tester. Refer to Figure
36.
^
Connect other end of K1-124 to the VCL. See Figure 36.
^
Turn the switch on the cable to the OFF position.
^
Insert the power cable of the NGS tester into the vehicle222s cigar lighter.
^
The NGS tester will display:
^
Using selector knob on NGS tester, select "VCL Reprogram."
^
Press the trigger button on the NGS tester.