Connect P120 to J120 at the tank valve solenoid. If Safety Recall 97573 has been performed, the connector ends will be taped to ribbed vent
hoses. See Figure 38.

^

NOTE

The CNG fuel tank must be completely full to perform the following steps. Turn off engine, switch selector to GFI position.

^

Open quarter turn valve in CNG system.

^

Start engine. Verify that the green GFI light remains illuminated.

^

Raise vehicle.

^

Leak test all connections from the intake manifold to the CNG tank, including all tank connections, compuvalve, regulator, filter, quarter turn
valve and all fittings using Snoop or a mild soap and water solution.

^

Repair any leaks discovered. Never attempt to tighten or adjust fittings while system is under pressure. Close tank valve and bleed system to