ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Recall - Blower Resistor Inspection/Replacement|Page 8569 > < Recall - Blower Resistor Inspection/Replacement|Page 8567
Page 5
background image

E.

Test the integrity of the splice after crimping. Grasp the wires and pull gently. If either wire is not attached securely, replace the splice
connector and crimp firmly.

F.

Repeat steps A through E for the remaining three (3) wires, one at a time.

G.

Heat each splice connector thoroughly until the tubing shrinks and adhesive flows from each end. Use Rotunda Heat Gun R07-10300 or
equivalent. See Figure 3.

3.

Install the new blower resistor (part no. YS4Z-18591-AA).

4.

Connect the new resistor jumper wire to the new blower resistor.

5.

Check operation of the blower motor.

6.

Install the right-hand upper foot well trim panel (if removed).

Recall - Blower Resistor Inspection/Replacement|Page 8569 > < Recall - Blower Resistor Inspection/Replacement|Page 8567